Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3935 PID: SPN: 5848 FMI: 13 Aftertreatment 1 SCR Intermediate NH3 Sensor- Out of Calibration

Circuit DescriptionThe aftertreatment SCR intermediate NH3 (ammonia) sensor is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment intermediate NH3 sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module using the J1939 data link. The aftertreatment intermediate NH3 sensor is used to measure the ammonia in the aftertreatment system.

Component LocationThe aftertreatment SCR intermediate NH3 sensor is located in the middle of the aftetreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftertreatment SCR intermediate temperature has been above 170 C [338 F] for a calibratible period of time while the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment SCR intermediate NH3 sensor reported the resistance of the trim resistor is out of range.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment SCR intermediate temperature must be above 170 C [338 F] for 5 seconds before the aftertreatment SCR intermediate NH3 sensor can run its internal diagnostics.

The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment SCR intermediate NH3 sensor probeA malfunctioning aftertreatment SCR intermediate NH3 sensor module

Possible Cause:1) NH3 sensor probe failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3934 PID: SPN: 5851 FMI: 2 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3933 PID: SPN: 5851 FMI: 18 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3932 PID: SPN: 5851 FMI: 16 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3912 PID: SPN: 5853 FMI: 10 Aftertreatment 1 Outlet NH3 Gas Sensor Heater- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3911 PID: SPN: 5848 FMI: 9 Aftertreatment 1 SCR Intermediate NH3 Sensor- Abnormal Update Rate
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3899 PID: SPN: 5848 FMI: 4 Aftertreatment 1 SCR Intermediate NH3 Sensor- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3936 PID: SPN: 5848 FMI: 12 Aftertreatment 1 SCR Intermediate NH3 Sensor- Bad Intelligent Device or Component

Circuit DescriptionThe aftertreatment SCR intermediate NH3 (ammonia) sensor is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment intermediate NH3 sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module using the J1939 data link. The aftertreatment intermediate NH3 sensor is used to measure the ammonia in the aftertreatment system.

Component LocationThe aftertreatment SCR intermediate NH3 sensor is located in the middle of the aftetreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment SCR intermediate NH3 sensor reported an internal circuitry error of the aftertreatment SCR intermediate NH3 sensor module.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment SCR intermediate NH3 sensor module

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3935 PID: SPN: 5848 FMI: 13 Aftertreatment 1 SCR Intermediate NH3 Sensor- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3934 PID: SPN: 5851 FMI: 2 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3933 PID: SPN: 5851 FMI: 18 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3932 PID: SPN: 5851 FMI: 16 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3912 PID: SPN: 5853 FMI: 10 Aftertreatment 1 Outlet NH3 Gas Sensor Heater- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3911 PID: SPN: 5848 FMI: 9 Aftertreatment 1 SCR Intermediate NH3 Sensor- Abnormal Update Rate

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3937 PID: SPN: 5848 FMI: 10 Aftertreatment 1 SCR Intermediate NH3 Sensor- Abnormal Rate of Change

Circuit DescriptionThe aftertreatment SCR intermediate NH3 (ammonia) sensor is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment intermediate NH3 sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module using the J1939 data link. The aftertreatment intermediate NH3 sensor is used to measure the ammonia in the aftertreatment system.

Component LocationThe aftertreatment SCR intermediate NH3 sensor is located in the middle of the aftetreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftertreatment SCR intermediate temperature has been above 170 C [338 F] for a calibratible period of time while the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment SCR intermediate NH3 Sensor reading was not valid.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment SCR intermediate temperature must be above 170 C [338 F] for 5 seconds before the aftertreatment SCR intermediate NH3 sensor can run its internal diagnostics.

The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment SCR intermediate NH3 sensor probeA malfunctioning aftertreatment SCR intermediate NH3 sensor module

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3936 PID: SPN: 5848 FMI: 12 Aftertreatment 1 SCR Intermediate NH3 Sensor- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3935 PID: SPN: 5848 FMI: 13 Aftertreatment 1 SCR Intermediate NH3 Sensor- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3934 PID: SPN: 5851 FMI: 2 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3933 PID: SPN: 5851 FMI: 18 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3932 PID: SPN: 5851 FMI: 16 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3912 PID: SPN: 5853 FMI: 10 Aftertreatment 1 Outlet NH3 Gas Sensor Heater- Abnormal Rate of Change

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4143 PID: SPN: 5835 FMI: 3 Aftertreatment 1 Particulate Sensor Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesAn internal circuit error was detected in the aftertreatment particulate sensor assembly

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Malfunctioning aftertreatment particulate matter sensor

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3937 PID: SPN: 5848 FMI: 10 Aftertreatment 1 SCR Intermediate NH3 Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3936 PID: SPN: 5848 FMI: 12 Aftertreatment 1 SCR Intermediate NH3 Sensor- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3935 PID: SPN: 5848 FMI: 13 Aftertreatment 1 SCR Intermediate NH3 Sensor- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3934 PID: SPN: 5851 FMI: 2 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3933 PID: SPN: 5851 FMI: 18 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3932 PID: SPN: 5851 FMI: 16 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Valid But Above Normal Operating Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4144 PID: SPN: 5835 FMI: 4 Aftertreatment 1 Particulate Sensor Circuit- Voltage Below Or Shorted to Low Source

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesAn internal circuit error was detected in the aftertreatment particulate sensor assembly

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Malfunctioning aftertreatment particulate matter sensor

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4143 PID: SPN: 5835 FMI: 3 Aftertreatment 1 Particulate Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3937 PID: SPN: 5848 FMI: 10 Aftertreatment 1 SCR Intermediate NH3 Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3936 PID: SPN: 5848 FMI: 12 Aftertreatment 1 SCR Intermediate NH3 Sensor- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3935 PID: SPN: 5848 FMI: 13 Aftertreatment 1 SCR Intermediate NH3 Sensor- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3934 PID: SPN: 5851 FMI: 2 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3933 PID: SPN: 5851 FMI: 18 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Valid But Below Normal Operating Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4149 PID: SPN: 2623 FMI: 8 Accelerator Pedal or Lever Position Sensor 2 Circuit Frequency- Abnormal frequency or Pulse width or Period

Circuit DescriptionThe accelerator pedal contains two position sensors. These position sensors are used to measure the throttle position. Both position sensors receive a 5 volt supply from the ECM. A corresponding signal voltage based on the position of the accelerator pedal is then received from the ECM. The signal voltage for accelerator position 1 is twice as much as the signal voltage from the accelerator position 2.

Component LocationThe accelerator pedal or lever position sensor is mounted to the accelerator pedal assembly. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the accelerator pedal position sensor reading was out of range.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The engine will have limp-home throttle control only.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning accelerator pedal position sensor.

A short circuit to battery in the OEM harnessA short circuit to ground in the OEM harnessAn open circuit in the OEM harness

Possible Cause:1) OEM harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4144 PID: SPN: 5835 FMI: 4 Aftertreatment 1 Particulate Sensor Circuit- Voltage Below Or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4143 PID: SPN: 5835 FMI: 3 Aftertreatment 1 Particulate Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3937 PID: SPN: 5848 FMI: 10 Aftertreatment 1 SCR Intermediate NH3 Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3936 PID: SPN: 5848 FMI: 12 Aftertreatment 1 SCR Intermediate NH3 Sensor- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3935 PID: SPN: 5848 FMI: 13 Aftertreatment 1 SCR Intermediate NH3 Sensor- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3934 PID: SPN: 5851 FMI: 2 Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 415 PID: PID 100 SPN: 100 FMI: 1 Engine Oil Rifle Pressure- Data Valid But Below Normal Operational Range- Most Severe Level

Circuit DescriptionAn engine oil pressure switch or oil pressure sensor is used by the engine control module (ECM) to monitor the lubricating oil pressure. For engines with an oil pressure switch, the switch is normally closed when the engine is not running and open when oil pressure is present. For engines with an oil pressure sensor, the ECM will detect a low signal voltage at operating conditions when the oil pressure is low. The ECM will detect a high signal voltage at operating conditions when the oil pressure is high.

Component LocationThe engine oil pressure sensor is located in the oil rifle.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine oil pressure was below minimum operating limits.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp immediately after the diagnostic runs and fails.The torque output of the engine will be reduced.The engine will be shut down if the Engine Protection Shutdown feature is enabled.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Low oil pressureIncorrect oil levelDamaged oil pressure switchEngine harness shorted to ground.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 386 PID: SID 212 SPN: 3509 FMI: 3 Sensor Supply 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 352 PID: SID 212 SPN: 3509 FMI: 4 Sensor Supply 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 351 PID: PID 110 SPN: 627 FMI: 12 Injector Power Supply- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 346 PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory Software- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 343 PID: SID 254 SPN: 629 FMI: 12 Engine Control Module Warning Internal Hardware Failure- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 339 PID: SID 87 SPN: 1267 FMI: 4 Idle Shutdown Vehicle Accessories Relay Driver Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4151 PID: SPN: 5742 FMI: 9 Aftertreatment Diesel Particulate Filter Temperature Sensor Module- Abnormal Update Rate

Circuit DescriptionThe aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel partculate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment diesel particulate filter temperature sensor module is mounted on the aftertreatment diesel particulate filter.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a loss of communication with the aftertreatment diesel particulate filter temperature sensor module.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Active and stationary regeneration of the diesel particulate filter will be disabled.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Low battery voltage supplyIncorrect terminating resistance of the SAE J1939 datalink circuitIncorrect Battery System Voltage setting in INSITEIncorrect sensor for the application (12 VDC versus 24 VDC)

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4149 PID: SPN: 2623 FMI: 8 Accelerator Pedal or Lever Position Sensor 2 Circuit Frequency- Abnormal frequency or Pulse width or Period
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4144 PID: SPN: 5835 FMI: 4 Aftertreatment 1 Particulate Sensor Circuit- Voltage Below Or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4143 PID: SPN: 5835 FMI: 3 Aftertreatment 1 Particulate Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3937 PID: SPN: 5848 FMI: 10 Aftertreatment 1 SCR Intermediate NH3 Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3936 PID: SPN: 5848 FMI: 12 Aftertreatment 1 SCR Intermediate NH3 Sensor- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3935 PID: SPN: 5848 FMI: 13 Aftertreatment 1 SCR Intermediate NH3 Sensor- Out of Calibration

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4152 PID: SPN: 5743 FMI: 9 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module- Abnormal Update Rate

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a loss of communication with the aftertreatment SCR temperature sensor module.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Low battery voltage supplyIncorrect terminating resistance of the SAE J1939 datalink circuitIncorrect sensor for the application (12 VDC versus 24 VDC)Incorrect Battery System Voltage setting in INSITE

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4151 PID: SPN: 5742 FMI: 9 Aftertreatment Diesel Particulate Filter Temperature Sensor Module- Abnormal Update Rate
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4149 PID: SPN: 2623 FMI: 8 Accelerator Pedal or Lever Position Sensor 2 Circuit Frequency- Abnormal frequency or Pulse width or Period
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4144 PID: SPN: 5835 FMI: 4 Aftertreatment 1 Particulate Sensor Circuit- Voltage Below Or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4143 PID: SPN: 5835 FMI: 3 Aftertreatment 1 Particulate Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3937 PID: SPN: 5848 FMI: 10 Aftertreatment 1 SCR Intermediate NH3 Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3936 PID: SPN: 5848 FMI: 12 Aftertreatment 1 SCR Intermediate NH3 Sensor- Bad Intelligent Device or Component

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4153 PID: SPN: 7321 FMI: 3 Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesAn internal circuit error was detected in the aftertreatment particulate sensor assembly

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Malfunctioning aftertreatment particulate matter sensor

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4152 PID: SPN: 5743 FMI: 9 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module- Abnormal Update Rate
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4151 PID: SPN: 5742 FMI: 9 Aftertreatment Diesel Particulate Filter Temperature Sensor Module- Abnormal Update Rate
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4149 PID: SPN: 2623 FMI: 8 Accelerator Pedal or Lever Position Sensor 2 Circuit Frequency- Abnormal frequency or Pulse width or Period
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4144 PID: SPN: 5835 FMI: 4 Aftertreatment 1 Particulate Sensor Circuit- Voltage Below Or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4143 PID: SPN: 5835 FMI: 3 Aftertreatment 1 Particulate Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3937 PID: SPN: 5848 FMI: 10 Aftertreatment 1 SCR Intermediate NH3 Sensor- Abnormal Rate of Change

Read more →