Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3681 PID: PID 411 SPN: 3228 FMI: 2 Aftertreatment Outlet Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftertreatment SCR outlet temperature has been above 200°C [392° F] for 60 seconds while the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the power supply to the outlet NOx sensor was above or below a calibratible threshold.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment SCR outlet temperature must be above 200° C [392° F] for 60 seconds before the aftertreatment outlet NOx sensor can run its internal diagnostics.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Short to battery or ground in the OEM harnessOpen NOx sensor power supply circuit in the OEM harnessIncorrect system voltage set-up in INSITE™ electronic service toolInternal malfunction of the outlet NOx sensorThe NOx sensor part number is incorrect.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment Outlet NOx sensor failure2) Loose Connections3) Battery failure4) OEM harness5) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3649 PID: SPN: 5024 FMI: 10 Aftertreatment Intake Nox Sensor Heater- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3596 PID: SPN: 4334 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3583 PID: SPN: 5031 FMI: 10 Aftertreatment Outlet Nox Sensor Heater- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3582 PID: SPN: 4364 FMI: 18 Aftertreatment SCR Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3578 PID: SPN: 4376 FMI: 4 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3577 PID: SPN: 4376 FMI: 3 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3682 PID: PID 190 SPN: 3218 FMI: 2 Aftertreatment Intake Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

Component LocationThe aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftetreatment diesel oxidation catalsyst intake temperature sensor has been above 150° C [302° F] for 5 seconds while the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the power supply to the intake NOx sensor was above or below a calibratible threshold.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment diesel oxidation catalyst intake temperature must be above 150° C [302° F] for 5 seconds before the aftertreatment intake NOx sensor can run its internal diagnostics.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Short to battery or ground in the OEM harnessOpen NOx sensor power supply circuit in the OEM harnessIncorrect system voltage set-up in INSITE™ electronic service toolInternal malfunction of the intake NOx sensorThe NOx sensor part number is incorrect.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment Intake NOx sensor failure2) Loose Connections3) Battery failure4) Engine harness5) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3681 PID: PID 411 SPN: 3228 FMI: 2 Aftertreatment Outlet Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3649 PID: SPN: 5024 FMI: 10 Aftertreatment Intake Nox Sensor Heater- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3596 PID: SPN: 4334 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3583 PID: SPN: 5031 FMI: 10 Aftertreatment Outlet Nox Sensor Heater- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3582 PID: SPN: 4364 FMI: 18 Aftertreatment SCR Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3578 PID: SPN: 4376 FMI: 4 Aftertreatment Diesel Exhaust Fluid Return Valve- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3697 PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory- Bad Intelligent Device or Component

Circuit DescriptionThe ECM has internal diagnostics that continuously run and check the internal memory.

Component LocationThe ECM mounting location varies, depending on the engine model, and may be mounted either on or off the engine.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a software or calibration error.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.

The engine may not start.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunction of the ECM software.

Possible Cause:1) N/A

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3682 PID: PID 190 SPN: 3218 FMI: 2 Aftertreatment Intake Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3681 PID: PID 411 SPN: 3228 FMI: 2 Aftertreatment Outlet Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3649 PID: SPN: 5024 FMI: 10 Aftertreatment Intake Nox Sensor Heater- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3596 PID: SPN: 4334 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3583 PID: SPN: 5031 FMI: 10 Aftertreatment Outlet Nox Sensor Heater- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3582 PID: SPN: 4364 FMI: 18 Aftertreatment SCR Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3712 PID: PID 105 SPN: 5246 FMI: 0 Aftertreatment SCR Operator Inducement- Data valid But Above Normal Operational Range- Most Severe Level

Circuit DescriptionThe ECM continuously monitors the engine’s fault code status to determine if any fault codes critical to successful engine operation are active.

Component LocationThe ECM mounting location varies, depending on the engine model, and may be mounted either on or off the engine.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine has been operated for an extended amount of time with critical SCR faults active, and no repair action has been taken. This amount of time will vary, depending on which SCR faults are active.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp immediately after the diagnostic runs and fails.Engine Torque will be reduced.Vehicle speed will be limited to 8 km [5 mi] per hour.Conditions for Clearing the Fault CodeThis fault code will go inactive once all other active fault codes have been addressed. Refer to the appropriate fault code troubleshooting tree.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.

Shop TalkThis fault code is for information only, and indicates that an engine power derate and vehicle speed limit have been implemented in order to make sure that the critical SCR related fault codes that are presently active in the ECM are addressed as quickly as possible.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3697 PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3682 PID: PID 190 SPN: 3218 FMI: 2 Aftertreatment Intake Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3681 PID: PID 411 SPN: 3228 FMI: 2 Aftertreatment Outlet Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3649 PID: SPN: 5024 FMI: 10 Aftertreatment Intake Nox Sensor Heater- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3596 PID: SPN: 4334 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3583 PID: SPN: 5031 FMI: 10 Aftertreatment Outlet Nox Sensor Heater- Abnormal Rate of Change

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3714 PID: SID 115 SPN: 1569 FMI: 31 Engine Protection Torque Derate- Condition Exists

Circuit DescriptionThe ECM continuously monitors the engine’s fault code status to determine if any fault codes critical to successful engine operation are active.

Component LocationThe ECM mounting location varies, depending on the engine model, and may be mounted either on or off the engine.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected that certain critical fault codes related to engine operation were active and the engine continued to operate.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Engine Torque will be reduced.Conditions for Clearing the Fault CodeThis fault code will go inactive once all other active fault codes have been addressed. Refer to the appropriate fault code troubleshooting tree.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.

Shop TalkThis fault code is for information only, and indicates that an engine power derate has been implemented in order to make sure that the critical fault codes that are presently active in the ECM are addressed as quickly as possible.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3712 PID: PID 105 SPN: 5246 FMI: 0 Aftertreatment SCR Operator Inducement- Data valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3697 PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3682 PID: PID 190 SPN: 3218 FMI: 2 Aftertreatment Intake Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3681 PID: PID 411 SPN: 3228 FMI: 2 Aftertreatment Outlet Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3649 PID: SPN: 5024 FMI: 10 Aftertreatment Intake Nox Sensor Heater- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3596 PID: SPN: 4334 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3715 PID: SPN: 188 FMI: 16 Engine Speed At Idle- Data Valid But Below Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe Engine Control Module (ECM) continuously monitors the engine speed at idle and adjusts fueling to maintain governed idle speed.

Component LocationThe engine speed is monitored by the crankshaft and/or camshaft position sensors.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is operating at idle and PTO is not active.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine speed was 50 rpm above governed idle speed for 30 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Fuel system malfunctionCrankshaft position sensor malfunctionCamshaft position sensor malfunctionAlternate fuel source entering intake system

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3714 PID: SID 115 SPN: 1569 FMI: 31 Engine Protection Torque Derate- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3712 PID: PID 105 SPN: 5246 FMI: 0 Aftertreatment SCR Operator Inducement- Data valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3697 PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3682 PID: PID 190 SPN: 3218 FMI: 2 Aftertreatment Intake Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3681 PID: PID 411 SPN: 3228 FMI: 2 Aftertreatment Outlet Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3649 PID: SPN: 5024 FMI: 10 Aftertreatment Intake Nox Sensor Heater- Abnormal Rate of Change

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3716 PID: SPN: 188 FMI: 18 Engine Speed At Idle- Data Valid But Below Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe Engine Control Module (ECM) continuously monitors the engine speed at idle and adjusts fueling to maintain governed idle speed.

Component LocationThe engine speed is monitored by the crankshaft and/or camshaft position sensors.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is operating at idle and PTO is not active.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine speed was 50 rpm below governed idle speed for 30 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Fuel system malfunctionCrankshaft position sensor malfunctionCamshaft position sensor malfunctionIncreased engine accessory load

Possible Cause:1) Crankshaft engine speed sensor, and camshaft engine position Sensor2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3715 PID: SPN: 188 FMI: 16 Engine Speed At Idle- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3714 PID: SID 115 SPN: 1569 FMI: 31 Engine Protection Torque Derate- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3712 PID: PID 105 SPN: 5246 FMI: 0 Aftertreatment SCR Operator Inducement- Data valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3697 PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3682 PID: PID 190 SPN: 3218 FMI: 2 Aftertreatment Intake Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3681 PID: PID 411 SPN: 3228 FMI: 2 Aftertreatment Outlet Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3724 PID: PID 168 SPN: 168 FMI: 17 Battery 1 Voltage- Data Valid But Below Normal Operating Range- Least Severe Level

Circuit DescriptionThe EGR valve device driver in the ECM provides power to the EGR valve motor. The EGR valve motor is used to move the EGR valve to the correct position, as commanded by the ECM.

Component LocationThe EGR valve device driver is internal to the ECM and can not be serviced separately.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected low power at the EGR valve device driver. The ECM was no longer able to control the EGR valve.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code indicates an internal failure in the ECM.

Possible Cause:1) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3716 PID: SPN: 188 FMI: 18 Engine Speed At Idle- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3715 PID: SPN: 188 FMI: 16 Engine Speed At Idle- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3714 PID: SID 115 SPN: 1569 FMI: 31 Engine Protection Torque Derate- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3712 PID: PID 105 SPN: 5246 FMI: 0 Aftertreatment SCR Operator Inducement- Data valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3697 PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3682 PID: PID 190 SPN: 3218 FMI: 2 Aftertreatment Intake Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3725 PID: PID 102 SPN: 3216 FMI: 10 Aftertreatment Intake Nox Sensor- Abnormal Rate of Change

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

Component LocationThe aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftetreatment diesel oxidation catalsyst intake temperature sensor has been above 150° C [302° F] for 5 seconds while the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment intake Nox sensor reading was not valid.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment diesel oxidation catalyst intake temperature must be above 150° C [302° F] for 5 seconds before the aftertreatment intake NOx sensor can run its internal diagnostics.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code sets when the aftertreatment intake NOx sensor indicates to the ECM that it is not providing valid data.Troubleshoot the aftertreatment outlet NOx sensor for Fault Codes 1885, 3232, or 3681 before troubleshooting this fault code.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3724 PID: PID 168 SPN: 168 FMI: 17 Battery 1 Voltage- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3716 PID: SPN: 188 FMI: 18 Engine Speed At Idle- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3715 PID: SPN: 188 FMI: 16 Engine Speed At Idle- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3714 PID: SID 115 SPN: 1569 FMI: 31 Engine Protection Torque Derate- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3712 PID: PID 105 SPN: 5246 FMI: 0 Aftertreatment SCR Operator Inducement- Data valid But Above Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3697 PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory- Bad Intelligent Device or Component

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3727 PID: SID 254 SPN: 5571 FMI: 7 High-Pressure Common Rail Fuel Pressure Relief Valve- Mechanical System Not Responding or Out of Adjustment

Circuit DescriptionThe high-pressure relief valve is a mechanical device that opens when the fuel pressure in the fuel rail exceeds a critical warning limit.

Component LocationThe high-pressure fuel pump is mounted to the gear housing. The fuel pump actuator is mounted on the fuel pump. The fuel pressure sensor is mounted in the high pressure fuel rail. The fuel pressure relief valve is mounted on the high pressure fuel rail.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the fuel pressure relief valve had opened at a pressure lower than expected.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeThe fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code will become inactive at each key OFF event, and will not become active again until the fault condition reoccurs. Troubleshoot inactive or active occurences of this fault code the same.

An occurence of this fault indicates that the high-pressure relief valve is being tripped at a pressure lower than what is expected. If this has happened multiple times, there will be many occurences of this fault. Troubleshoot Fault Code 3727 before Fault Code 1911, if both fault codes are present in the ECM.

This fault code may also be triggered by a sudden and significant loss of fuel pressure in the fuel system.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3725 PID: PID 102 SPN: 3216 FMI: 10 Aftertreatment Intake Nox Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3724 PID: PID 168 SPN: 168 FMI: 17 Battery 1 Voltage- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3716 PID: SPN: 188 FMI: 18 Engine Speed At Idle- Data Valid But Below Normal Operating Range- Moderately Severe Level