Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2376 PID: PID 412 SPN: 412 FMI: 4 Exhaust Gas Recirculation Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe exhaust gas recirculation (EGR) temperature sensor is a variable resistor sensor and is used to measure the temperature of the EGR gas flow after it exits the EGR cooler. The engine control module (ECM) supplies 5 volts to the EGR temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the EGR flow temperature.

The EGR temperature value is used by the ECM for the engine protection system and engine emissions control.

Component LocationThe EGR temperature sensor is located on the EGR connection tube between the EGR cooler and the air intake connection.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the EGR temperature signal voltage was less than 0.05-VDC for more than 8 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value for the exhaust gas recirculation temperature reading is used.Diesel exhaust fluid injection into the aftertreatment system is disabled.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe EGR temperature sensor shares return wires in the engine harness with other sensors. An open return can cause multiple fault codes to be active.

Possible causes of this fault code include:

A signal shorted to ground in the harnessA signal shorted to return or ground in the sensor.

Possible Cause:1) ECM failure2) Engine harness

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2375 PID: PID 412 SPN: 412 FMI: 3 Exhaust Gas Recirculation Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2374 PID: PID 131 SPN: 1209 FMI: 4 Exhaust Gas Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2373 PID: PID 131 SPN: 1209 FMI: 3 Exhaust Gas Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2372 PID: PID 95 SPN: 95 FMI: 16 Fuel Filter Differential Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2367 PID: SID 80 SPN: 1073 FMI: 3 Engine Brake Actuator Driver Output 2 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2363 PID: SID 80 SPN: 1073 FMI: 4 Engine Brake Actuator Driver Output 2 Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2377 PID: SID 33 SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe fan control circuit is a device used by the engine to control the fan operation. When the engine control module (ECM) energizes the fan control circuit, the engine fan is engaged.

The fan control circuit utilizes a pulse width modulated (PWM) signal. A PWM signal is a pulsed voltage signal between 0-VDC and system voltage. The frequency of the pulsed voltage signal is dependent on the application requirement.

There are two types of fans supported by the fan control circuit; variable speed and ON/OFF. INSITE™ electronic service tool can be used to determine which fan type is currently set up for use. The fan control circuit varies by original equipment manufacturer (OEM). Certain OEMs can use a solenoid return that is wired to the ECM or can use a return that goes to the engine block or chassis ground.

Component LocationThe control solenoid location varies by OEM. Refer to the appropriate OEM service manual to determine the location.

Conditions for Running the DiagnosticsFor ON/OFF and variable speed fan types, the diagnostic runs when the fan is turned off and will latch active when the fan PWM signal is 100 percent. For all other fan types, the diagnostic runs when the fan PWM signal is less than 100 percent and will latch active when the fan PWM signal is 100 percent.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the fan control circuit pulse width modulated (PWM) signal voltage was greater then 0-VDC when the PWM signal was commanded OFF.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Fan operation will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and leave the key in the ON position for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkIf Fault Code 2377 is still active after completing all the steps in this fault code troubleshooting tree, consult the OEM service literature for procedures to check the fan clutch device for an open circuit or short circuit to ground.

Possible causes of this fault include:

An open circuit in the harness or fan control solenoid.A short circuit to voltage source in the OEM harness.A malfunctioning ECM.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Fan Control Solenoid failure2) OEM harness3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2376 PID: PID 412 SPN: 412 FMI: 4 Exhaust Gas Recirculation Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2375 PID: PID 412 SPN: 412 FMI: 3 Exhaust Gas Recirculation Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2374 PID: PID 131 SPN: 1209 FMI: 4 Exhaust Gas Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2373 PID: PID 131 SPN: 1209 FMI: 3 Exhaust Gas Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2372 PID: PID 95 SPN: 95 FMI: 16 Fuel Filter Differential Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2367 PID: SID 80 SPN: 1073 FMI: 3 Engine Brake Actuator Driver Output 2 Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 238 PID: PID 105 SPN: 3511 FMI: 4 Sensor Supply 3 Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe sensor supply 3 circuit provides a 5 volt supply to the primary engine speed/position sensor.

Component LocationSensor Supply 3 originates in the engine wiring harness. It provides 5 VDC to the engine crankshaft speed/position sensor.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the sensor supply 3 signal voltage was less than a 4.8-VDC for more than 1 second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The backup engine speed sensor will be used by the ECM for the engine speed signal.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe ECM monitors the voltage level on the engine speed sensor +5 volt supply circuit. If the voltage falls below a calibratible limit, this fault is recorded.

Possible causes of this fault code:

Short circuit to ground in the engine harness, sensor, or ECM.

Possible Cause:1) Crankshaft Position sensor failure2) Engine harness

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 235 PID: PID 111 SPN: 111 FMI: 1 Coolant Level- Data Valid But Below Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 234 PID: PID 190 SPN: 190 FMI: 0 Engine Crankshaft Speed/Position- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 227 PID: SID 211 SPN: 3510 FMI: 3 Sensor Supply 2 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 222 PID: PID 108 SPN: 108 FMI: 4 Barometric Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 221 PID: PID 108 SPN: 108 FMI: 3 Barometric Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 214 PID: PID 175 SPN: 175 FMI: 0 Engine Oil Temperature- Data Valid But Above Normal Operating Range- Most Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2387 PID: SID 27 SPN: 641 FMI: 7 VGT Actuator Driver Circuit (Motor)- Mechanical System Not Responding or Out Of Adjustment

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault CodesThe Variable Geometry Turbocharger (VGT) actuator position could not meet the commanded position for greater than 10 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

The VGT actuator will continue to attempt to meet commanded position, even when the CHECK ENGINE lamp is on.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning turbochargerA malfunctioning turbocharger actuatorThe aftertreatment system must be inspected for potential damage after making the appropriate repair outlined in this fault code troubleshooting tree. Progressive damage to the aftertreatment system can possibly have occurred.

Possible Cause:1) Turbocharger assembly failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2377 PID: SID 33 SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2376 PID: PID 412 SPN: 412 FMI: 4 Exhaust Gas Recirculation Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2375 PID: PID 412 SPN: 412 FMI: 3 Exhaust Gas Recirculation Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2374 PID: PID 131 SPN: 1209 FMI: 4 Exhaust Gas Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2373 PID: PID 131 SPN: 1209 FMI: 3 Exhaust Gas Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2372 PID: PID 95 SPN: 95 FMI: 16 Fuel Filter Differential Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 239 PID: SID 232 SPN: 3511 FMI: 3 Sensor Supply 3 Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe sensor supply 3 circuit provides a 5 volt supply to the primary engine speed/position sensor.

Component LocationSensor Supply 3 originates in the engine wiring harness. It provides 5 VDC to the engine crankshaft speed/position sensor.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the sensor supply 3 signal voltage was greater than 5.25-VDC for more than 1 second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The backup engine speed sensor will be used by the ECM for the engine speed signal.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkHigh voltage on the +5 volt supply wire can be caused by a short to battery voltage in the engine harness or connectors, or a damaged ECM.

Possible Cause:1) Engine harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 238 PID: PID 105 SPN: 3511 FMI: 4 Sensor Supply 3 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 235 PID: PID 111 SPN: 111 FMI: 1 Coolant Level- Data Valid But Below Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 234 PID: PID 190 SPN: 190 FMI: 0 Engine Crankshaft Speed/Position- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 227 PID: SID 211 SPN: 3510 FMI: 3 Sensor Supply 2 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 222 PID: PID 108 SPN: 108 FMI: 4 Barometric Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 221 PID: PID 108 SPN: 108 FMI: 3 Barometric Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2398 PID: SPN: 171 FMI: 2 Ambient Air Temperature- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe ambient air temperature sensor is a variable resistor sensor and is used to measure the temperature of the ambient air. The engine control module (ECM) uses this temperature reading to optimize engine performance, and determine if heating of the SCR system is required. The engine control module (ECM) supplies 5 volts to the ambient air temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the ambient air temperature.

Component LocationThe mounting location for the ambient air temperature sensor is OEM dependent. Refer to the appropriate OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic consists of two parts. The first part runs when the keyswitch is turned ON and before engine speed is detected. The ECM must not see a key cycle for a period of 8 hours before this part of the diagnostic will run.

The second part runs continuously while the engine is running.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the ambient air temperature reading was higher or lower than the other temperature sensors on the engine after an extended period of engine off time, or the ambient air temperature was reading was too high or too low for the engine operating conditions.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value for the ambient air temperature reading is used.Active and stationary regeneration of the diesel particulate filter will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.If the fault code does not go inactive, it may be necessary to perform a 8 hour cold soak with the key OFF, then turn the keyswitch to the ON position so that the key ON portion of the diagnostic will run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Stuck in-range ambient air temperature sensorHigh resistance in the ambient air temperature sensor signal or return linesECM malfunction.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) OEM harness2) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2387 PID: SID 27 SPN: 641 FMI: 7 VGT Actuator Driver Circuit (Motor)- Mechanical System Not Responding or Out Of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2377 PID: SID 33 SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2376 PID: PID 412 SPN: 412 FMI: 4 Exhaust Gas Recirculation Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2375 PID: PID 412 SPN: 412 FMI: 3 Exhaust Gas Recirculation Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2374 PID: PID 131 SPN: 1209 FMI: 4 Exhaust Gas Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2373 PID: PID 131 SPN: 1209 FMI: 3 Exhaust Gas Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 241 PID: PID 84 SPN: 84 FMI: 2 Wheel-Based Vehicle Speed- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe vehicle speed sensor senses the speed of the tailshaft gear on the vehicle’s transmission. This speed signal is then transmitted to the engine control module (ECM) and converted into a vehicle speed.

Component LocationThe vehicle speed sensor is located in the rear of the vehicle transmission. Refer to the OEM service manual for location.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the vehicle is in motion, if the feature is enabled.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a loss of vehicle speed when other engine operating conditions indicated that the vehicle should be in motion. This fault code can also become active if the calculated gear ratio and actual gear ratio do not agree while the vehicle is in motion.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.The engine speed operating range is limited to the adjustable parameter “Maximum Engine Speed without VSS”.ECM powerdown will be delayed for 60 seconds after key OFF.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThere are multiple types of vehicle speed sensors. Various types include magnetic pickup, data link, digital, and tachograph. Contact the OEM for the specific type installed on the vehicle.

This fault is set active when the ECM loses a vehicle speed signal when other engine conditions indicate the vehicle is moving. The fault can also become active if there is a series of clutch, service brake or throttle movements with no vehicle movement. The fault is set inactive when the ECM receives a valid vehicle speed signal.

Since the vehicle speed sensor is an OEM installed component, this troubleshooting procedure will not cover all malfunctions of the circuit due to components not under Cummins Inc. control. Sensor resistance values, data link speed sensors and tachographs are not fully covered under this procedure. For more information on those components, refer to the OEM service manual.

A damaged vehicle speed sensor or debris on the end of the sensor could cause the fault to become active.

Incorrect INSITE™ electronic service tool feature and parameter settings (gear ratio, tire size, rear axle ratio, etc) will also cause the fault to become active. Feature and parameter settings under Transmission Setup and Vehicle Speed source need to be verified with the vehicle components.

NOTE: If the power is removed from the ECM within 60 seconds of key OFF and before the ECM has powered down, Fault Code 1117 may become active.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) OEM harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 239 PID: SID 232 SPN: 3511 FMI: 3 Sensor Supply 3 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 238 PID: PID 105 SPN: 3511 FMI: 4 Sensor Supply 3 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 235 PID: PID 111 SPN: 111 FMI: 1 Coolant Level- Data Valid But Below Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 234 PID: PID 190 SPN: 190 FMI: 0 Engine Crankshaft Speed/Position- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 227 PID: SID 211 SPN: 3510 FMI: 3 Sensor Supply 2 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 222 PID: PID 108 SPN: 108 FMI: 4 Barometric Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2416 PID: SID 253 SPN: 1634 FMI: 13 Engine Control Module Calibration Memory Checksum- Out of Calibration

Circuit DescriptionThe Engine Control Module (ECM) calculates a calibration memory checksum based on the values of certain parameters in the ECM. This checksum is compared to an expected value in the ECM to detect tampering.

Component LocationThe ECM mounting location varies, depending on the engine model, and may be mounted either on or off the engine.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the calibration memory checksum did not match the expected value or it did not complete before ECM shutdown.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeIn order for this fault code to go inactive, a calibration download is necessary.

The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.

Shop TalkPossible causes of this fault code include:

Malfunctioning ECM software

Tampering of the ECM software

Possible Cause:1) N/A

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2398 PID: SPN: 171 FMI: 2 Ambient Air Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2387 PID: SID 27 SPN: 641 FMI: 7 VGT Actuator Driver Circuit (Motor)- Mechanical System Not Responding or Out Of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2377 PID: SID 33 SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2376 PID: PID 412 SPN: 412 FMI: 4 Exhaust Gas Recirculation Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2375 PID: PID 412 SPN: 412 FMI: 3 Exhaust Gas Recirculation Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2374 PID: PID 131 SPN: 1209 FMI: 4 Exhaust Gas Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 242 PID: PID 84 SPN: 84 FMI: 10 Wheel-Based Vehicle Speed Sensor Circuit Tampering Has Been Detected- Abnormal Rate of Change

Circuit DescriptionThe vehicle speed sensor senses the speed of the tailshaft gear on the vehicle’s transmission. This speed signal is then transmitted to the engine control module (ECM) and converted into a vehicle speed.

Component LocationThe vehicle speed sensor is located in the rear of the vehicle transmission. Refer to the OEM service manual for location.

Conditions for Running the DiagnosticsThe adjustable parameter “VSS Anti-Tampering” must be enabled.This diagnostic runs continuously when the vehicle is in motion, if the feature is enabled.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a tampering event of the vehicle speed signal.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The engine speed operating range is limited to the adjustable parameter “Maximum Engine Speed without VSS”.Cruise Control, Gear-Down Protection, and Road Speed Governor features will be disabled.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkVerify that the feature settings for the vehicle speed sensor anti-tampering (Fault Code 242), application type and automatic transmission are set correctly. If any of these are set incorrectly for the specific vehicle and application, Fault Code 242 could occur erroneously.

Driving techniques such as driving for extended periods of time in lower gears can log Fault Code 242. Fault Code 242 can be logged if the driver attempts to defeat the road speed governor by repeatedly cycling the keyswitch.

Once the speed signal has been restored the fault code will go inactive once the keyswitch is ON for 30 seconds and the ECM senses zero vehicle and engine speed.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) OEM harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 241 PID: PID 84 SPN: 84 FMI: 2 Wheel-Based Vehicle Speed- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 239 PID: SID 232 SPN: 3511 FMI: 3 Sensor Supply 3 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 238 PID: PID 105 SPN: 3511 FMI: 4 Sensor Supply 3 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 235 PID: PID 111 SPN: 111 FMI: 1 Coolant Level- Data Valid But Below Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 234 PID: PID 190 SPN: 190 FMI: 0 Engine Crankshaft Speed/Position- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 227 PID: SID 211 SPN: 3510 FMI: 3 Sensor Supply 2 Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2448 PID: PID 2560 SPN: 111 FMI: 17 Coolant Level- Data Valid But Below Normal Operational Range- Least Severe Level

Circuit DescriptionThe coolant level sensor is a switch and is used to measure the level of the engine coolant in the radiator top tank. The coolant level sensor is immersed in the coolant and returns a different signal voltage when immersed in coolant versus being out of coolant. The engine control module (ECM) monitors the change in the signal voltage to determine the level of the engine coolant.

Component LocationThe engine coolant level sensor is typically located in the radiator top tank or surge tank. Refer to the OEM service manual for the location.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the coolant level sensor signal voltage is between 1.75 VDC and 3 VDC for more than 30 seconds, indicating low coolant level.

Action Taken When the Fault Code is ActiveThe ECM flashes the amber CHECK ENGINE lamp, indicating a maintenance condition, immediately after the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the flashing amber CHECK ENGINE lamp / MAINTENANCE lamp immediately after the diagnostic runs and passes.

The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code goes active when the coolant level inside the radiator top tank or surge tank drops below the sensor level. Fill the top tank with coolant.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2416 PID: SID 253 SPN: 1634 FMI: 13 Engine Control Module Calibration Memory Checksum- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2398 PID: SPN: 171 FMI: 2 Ambient Air Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2387 PID: SID 27 SPN: 641 FMI: 7 VGT Actuator Driver Circuit (Motor)- Mechanical System Not Responding or Out Of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2377 PID: SID 33 SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2376 PID: PID 412 SPN: 412 FMI: 4 Exhaust Gas Recirculation Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2375 PID: PID 412 SPN: 412 FMI: 3 Exhaust Gas Recirculation Temperature Sensor Circuit- Voltage Above Normal or Shorted to High Source

Read more →