Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6261 PID: SPN: 677 FMI: 3 Engine Starter Motor Relay Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe starter lockout relay is controlled by the engine control module (ECM) through the starter lockout relay signal circuit. The relay prevents the starter from being engaged when the engine is running. The relay return circuit is dependent on OEM wiring. It can be wired back to the ECM on some vehicles or wired to chassis or block ground on others. Consult the OEM wiring diagram for return circuit details. The starter lockout relay circuit utilizes a pulse width modulated (PWM) signal. A PWM signal is a pulsed voltage signal between 0-VDC and system voltage. The frequency of the pulsed voltage signal is dependent on the application requirement.

Component LocationThe starter lockout relay is installed by the vehicle OEM. Refer to the OEM service manual for component location.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and when the pulse width modulated (PWM) device is getting energized or de-energized. In some cases, the diagnostics can also run at some fixed intervals.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the starter lockout relay pulse width modulated (PWM) signal was NOT at system voltage when the pulse width modulated (PWM) signal was commanded ON.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.The Starter Lockout feature will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe ECM monitors the voltage level on this circuit. If it detects a voltage when the signal is commanded off, it records this fault code. This fault code can be caused by:

Open circuit in the starter lockout relay, OEM harness, or connectorsShort circuit to a voltage source in the OEM harness or relay.This fault can also be set active if the over crank protection feature (starter lockout) is enabled, but the engine/ECM is not wired to support it.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Starter Lockout relay failure2) OEM harness3) ECM Failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6259 PID: SPN: 1075 FMI: 4 Electric Lift Pump For Engine Fuel Supply- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6258 PID: SPN: 1075 FMI: 3 Electric Lift Pump For Engine Fuel Supply- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6257 PID: SPN: 168 FMI: 17 Battery 1 Voltage- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6256 PID: SPN: 168 FMI: 15 Battery 1 Voltage- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6255 PID: SPN: 1569 FMI: 15 Engine Protection Torque Derate- Data Valid But Above Normal Operating Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6254 PID: SPN: 5246 FMI: 16 Aftertreatment SCR Operator Inducement Severity- Data Valid But Above Normal Operating Range- Moderately Severe Level