Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5868 PID: SPN: 4339 FMI: 7 Aftertreatment 1 SCR Feedback Control Status- Mechanical System Not Responding or Out of Adjustment

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

The aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

The aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the adjusted aftertreatment diesel exhaust fluid dosing command has reached a maximum limit.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeIt is necessary to use the “Reset All Faults” command in INSITE™ electronic service tool to clear this fault and extinguish the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL).

Shop TalkTroubleshoot other active SCR related faults before this fault.

Possible Cause:1) N/A

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5837 PID: SPN: 5835 FMI: 21 Aftertreatment 1 Particulate Sensor- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5793 PID: SPN: 7323 FMI: 3 Aftertreatment 1 Particulate Sensor Heater Low Side Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5792 PID: SPN: 7321 FMI: 4 Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5716 PID: SPN: 3610 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5715 PID: SPN: 3251 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Differential Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5689 PID: SPN: 3226 FMI: 11 Aftertreatment 1 Outlet Nox Sensor- Root Cause Not Known