Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5792 PID: SPN: 7321 FMI: 4 Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesAn internal circuit error was detected in the aftertreatment particulate sensor assembly

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Malfunctioning aftertreatment particulate matter sensor

Possible Cause:1) Battery failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5716 PID: SPN: 3610 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5715 PID: SPN: 3251 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Differential Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5689 PID: SPN: 3226 FMI: 11 Aftertreatment 1 Outlet Nox Sensor- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5655 PID: SPN: 4364 FMI: 31 Aftertreatment 1 SCR Conversion Efficiency- condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5584 PID: SPN: 6773 FMI: 7 Aftertreatment 1 Particulate Sensor Regeneration Status- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5583 PID: SPN: 6777 FMI: 10 Aftertreatment 1 Particulate Sensor Detection Status- Abnormal Rate of Change