Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5259 PID: SPN: 3667 FMI: 14 Engine Air Shutoff Status- Special Instructions

Circuit DescriptionThe engine control module (ECM) controls the engine intake air throttle actuator. The ECM can open and close the throttle based on the operating condtions in order to regulate air flow to the engine.

Component LocationThe engine intake air throttle actuator is mounted in the piping between the charge air cooler and intake manifold.

Possible Cause:1) ECM calibration

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected active Engine Intake Air Throttle faults.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp immediately after the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis is an information only fault that sets when there are one or more active Engine Intake Air Throttle faults when the Engine Intake Air Throttle has been configured as an Air Shutoff.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5221 PID: SPN: 3667 FMI: 2 Engine Air Shutoff Status- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5177 PID: SPN: 6713 FMI: 9 Variable Geometry Turbocharger Actuator Software- Abnormal Update Rate
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4957 PID: SPN: 6713 FMI: 31 Variable Geometry Turbocharger Actuator Software- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4956 PID: SPN: 6713 FMI: 13 Variable Geometry Turbocharger Actuator Software- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4952 PID: SPN: 6655 FMI: 4 Maintain ECU Power Lamp Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4951 PID: SPN: 6655 FMI: 3 Maintain ECU Power Lamp Circuit- Voltage Above Normal or Shorted to High Source