Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3571 PID: SPN: 4334 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe Engine Control Module (ECM) provides a 5 volt supply and a ground to the aftertreatment diesel exhaust fluid pressure sensor. The pressure sensor provides a signal to the ECM on the sensor signal circuit. This sensor signal voltage changes, based on the aftertreatment diesel exhaust fluid pressure supplied by the dosing unit. The ECM will detect a low signal voltage at low diesel exhaust fluid pressures, and a high signal voltage at high diesel exhaust fluid pressures.

Component LocationThe aftertreatment diesel exhaust fluid pressure sensor is internal to the aftertreatment diesel exhaust fluid dosing unit and can not be serviced separately.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid pressure sensor signal voltage was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Signal wire shorted to sensor supply or battery voltageA malfunctioning aftertreatment diesel exhaust fluid pressure sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) OEM harness2) ECM failure

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3568 PID: SPN: 5394 FMI: 7 Aftertreatment Diesel Exhaust Fluid (DEF) Dosing Valve- Mechanical System Not Responding or Out of Adjustment
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3567 PID: SPN: 5394 FMI: 5 Aftertreatment Diesel Exhaust Fluid Dosing Valve- Current Below Normal or Open Circuit
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3563 PID: SPN: 5491 FMI: 4 Aftertreatment Diesel Exhaust Fluid Line Heater Relay – Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3562 PID: SPN: 5491 FMI: 3 Aftertreatment Diesel Exhaust Fluid Line Heater relay – Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3559 PID: SPN: 3361 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3558 PID: SPN: 3361 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit- Voltage Above Normal or Shorted to High Source