Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3228 PID: SPN: 3216 FMI: 2 Aftertreatment 1 Intake Nox Sensor- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

Component LocationThe aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftetreatment diesel oxidation catalsyst intake temperature sensor has been above 150° C [302° F] for 5 seconds while the engine is running.

This diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment intake NOx reading was higher or lower than the calculated aftertreatment intake NOx value for the engine operating conditions.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, it may be necessary to operate the vehicle on a chassis dynamometer or to drive the vehicle in order to get the engine load high enough for the diagnostic to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

EGR system leaksExhaust system leaksAn incorrectly installed aftertreatment intake NOx sensorAn aftertreatment intake NOx sensor that has carbon buildup on the tip of the sensorA malfunctioning EGR differential pressure sensor.A malfunctioning EGR valveExcessive oil consumptionPossible engine misfireThe NOx sensor part number is incorrect.

Possible Cause:1) N/A

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3225 PID: SPN: 3490 FMI: 7 Aftertreatment Purge Air Actuator- Mechanical System Not Responding or Out of Adjustment
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3224 PID: SPN: 3490 FMI: 3 Aftertreatment Purge Air Actuator Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3223 PID: SPN: 3490 FMI: 4 Aftertreatment Purge Air Actuator Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3168 PID: SPN: 3936 FMI: 16 Aftertreatment Diesel Particulate Filter System- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3167 PID: SID 382 SPN: 3556 FMI: 18 Aftertreatment Doser- Data Valid But Below Normal Operaing Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3165 PID: SPN: 4363 FMI: 0 Aftertreatment 1 SCR Outlet Temperature- Data Valid But Above Normal Operating Range- Most Severe Level