Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2554 PID: PID 131 SPN: 1209 FMI: 2 Exhaust Gas Pressure- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe exhaust gas pressure sensor is used to measure exhaust gas pressure in the exhaust manifold. This information is used by the engine control module (ECM) to control emissions and exhaust gas recirculation (EGR) valve operation. The ECM provides a 5 volt supply to the exhaust gas pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The exhaust gas pressure sensor provides a signal to the ECM on the exhaust gas pressure sensor signal circuit. This sensor signal voltage changes, based on the pressure in the exhaust manifold.

Component LocationThe exhaust gas pressure sensor is located above the front section of the exhaust manifold and is plumbed into the exhaust manifold.

Conditions for Running the DiagnosticsThis diagnostic consists of two parts:

One part runs immediately after the keyswitch is turned OFF, and the engine coolant temperature is above 70°C or 158°F.

The second part runs continuously while the engine is running.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the exhaust pressure reading was higher or lower than the other absolute pressure sensors when the keyswitch is OFF and the engine is not running.The Engine Control Module (ECM) detected the exhaust pressure was higher or lower than expected during normal engine operation.Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value is used for the exhaust gas pressure sensor reading.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, first ensure the engine coolant temperature is above 70°C or 158°F. Operate the engine if necessary.Cycle the keyswitch to the ON position for 30 seconds, then cycle the keyswitch to the OFF position for 30 seconds. Start the engine and run it at high idle for up to 5 minutes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Stuck in-range exhaust gas pressure sensor readingHigh resistance in the exhaust gas pressure sensor signal or return linesPlugging or restriction in the exhaust gas pressure sensor tubeLeaks in the exhaust system

Possible Cause:1) Engine harness2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2468 PID: PID 190 SPN: 102 FMI: 3 Engine Crankshaft Speed/Position- Data valid But Above Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2451 PID: SID 384 SPN: 2789 FMI: 16 Turbocharger Turbine Intake Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2449 PID: SID 027 SPN: 641 FMI: 13 VGT Actuator Controller- Out of Calibration
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2448 PID: PID 2560 SPN: 111 FMI: 17 Coolant Level- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2416 PID: SID 253 SPN: 1634 FMI: 13 Engine Control Module Calibration Memory Checksum- Out of Calibration
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2398 PID: SPN: 171 FMI: 2 Ambient Air Temperature- Data Erratic, Intermittent, or Incorrect