Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Variable Geometry Turbocharger (VGT) actuator did not receive a valid J1939 data link message from the Engine Control Module (ECM) for 4 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.VGT actuation will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkIntermittent J1939 data link connections or interference on the J1939 network are possible causes of this fault code. Also check for intermittent power supply and ground connections to the VGT actuator.

Possible Cause:1) ECM failure

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2191 PID: PID 102 SPN: 102 FMI: 31 Intake Manifold 1 Pressure Sensor- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2186 PID: SID 232 SPN: 3512 FMI: 4 Sensor Supply 4 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2185 PID: SID 232 SPN: 3512 FMI: 3 Sensor Supply 4 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2183 PID: SID 79 SPN: 1072 FMI: 4 Engine Brake Actuator Driver 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2182 PID: SID 79 SPN: 1072 FMI: 3 Engine Brake Actuator Driver 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1981 PID: SPN: 3936 FMI: 15 Aftertreatment Diesel Particulate Filter System- Data Valid But Above Normal Operational Range- Least Severe Level