Meteen naar de content

Telegram : @Diezel365

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1885 PID: PID 102 SPN: 3216 FMI: 4 Aftertreatment Intake Nox Sensor Circuit- Voltage Below Normal, or Shorted to Low Source

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

Component LocationThe aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftetreatment diesel oxidation catalsyst intake temperature sensor has been above 150° C [302° F] for 5 seconds while the engine is running.

Conditions for Setting the Fault CodesAn internal circuit error was detected in the aftertreatment intake NOx sensor assembly.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be severely reduced.Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.

Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment diesel oxidation catalyst intake temperature must be above 150° C [302° F] for 5 seconds before the aftertreatment intake NOx sensor can run its internal diagnostics.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

The aftertreatment intake NOx sensor has malfunctioned or is damagedThe aftertreatment intake NOx sensor internal heater has malfunctionedThe NOx sensor part number is incorrect.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1883 PID: SID 324 SPN: 3251 FMI: 2 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1881 PID: SID 324 SPN: 3251 FMI: 4 Aftertreatment Diesel Particulate Filter Differential Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1879 PID: SID 324 SPN: 3251 FMI: 3 Aftertreatment Diesel Particulate Filter Differential Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1867 PID: PID 412 SPN: 412 FMI: 2 Exhaust Gas Recirculation Temperature- Data Erratic, Intermittent, Or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1866 PID: PID 411 SPN: 411 FMI: 2 Exhaust Gas Recirculation Differential Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1852 PID: SPN: 97 FMI: 16 Water-In-Fuel Indicator- Data Valid But Above Normal Operating Range- Moderately Severe Level