Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1881 PID: SID 324 SPN: 3251 FMI: 4 Aftertreatment Diesel Particulate Filter Differential Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the aftertreatment diesel particulate filter differential pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The aftertreatment diesel particulate filter differential pressure sensor provides a signal to the ECM on the aftertreatment diesel particulate filter differential pressure sensor signal circuit. This sensor signal voltage changes, based on the differential pressure across the aftertreatment diesel particulate filter.

Component LocationThe aftertreatment diesel particulate filter differential pressure sensor is mounted on the diesel particulate filter. It is a combination sensor that detects both diesel particulate filter differential pressure and outlet pressure. Refer to the original equipment manufacturer (OEM) service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel particulate filter differential pressure signal voltage was less than 0.25-VDC for more than 2 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value of the aftertreatment diesel particulate filter differential pressure is used.Diesel exhaust fluid injection into the aftertreatment system is disabled.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Signal circuit open or shorted to ground in the engine harness or sensorSupply line open or shorted to ground.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) OEM harness2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1879 PID: SID 324 SPN: 3251 FMI: 3 Aftertreatment Diesel Particulate Filter Differential Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1867 PID: PID 412 SPN: 412 FMI: 2 Exhaust Gas Recirculation Temperature- Data Erratic, Intermittent, Or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1866 PID: PID 411 SPN: 411 FMI: 2 Exhaust Gas Recirculation Differential Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1852 PID: SPN: 97 FMI: 16 Water-In-Fuel Indicator- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1846 PID: PID 97 SPN: 97 FMI: 4 Water In Fuel Indicator Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1845 PID: PID 97 SPN: 97 FMI: 3 Water In Fuel Indicator Sensor Circuit- Voltage Above Normal or Shorted to High Source