Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1694 PID: PID 2201 SPN: 3226 FMI: 2 Aftertreatment 1 Outlet Nox Sensor- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment outlet NOx sensor reading was not changing with engine conditions or is stuck.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.To validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Diesel exhaust fluid crystallization or depositsIncorrectly installed aftertreatment outlet NOx sensorMalfunctioning aftertreatment outlet NOx sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

This diagnostic will NOT run during a regeneration.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) N/A

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1691 PID: SID 380 SPN: 5298 FMI: 18 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1686 PID: SPN: 3364 FMI: 3 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1685 PID: SPN: 3364 FMI: 4 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1684 PID: SPN: 3363 FMI: 4 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1683 PID: SPN: 3363 FMI: 3 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1682 PID: SPN: 3362 FMI: 31 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Input Lines- Condition Exists