Meteen naar de content

Telegram : @Diezel365

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 124 PID: PID 102 SPN: 102 FMI: 16 Intake Manifold 1 Pressure- Data valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the intake manifold pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The intake manifold pressure sensor provides a signal to the ECM on the intake manifold pressure sensor signal circuit. This sensor signal voltage changes based on the pressure in the intake manifold.

Component LocationThe intake manifold 1 pressure/temperature sensor is located in the air intake horn.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the intake manifold pressure reading was higher than expected for the engine operating conditions.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning variable geometry turbocharger (VGT)High exhaust restriction.Malfunctioning intake manifold pressure/temperature sensor

Possible Cause:1) Intake manifold pressure sensor failure2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 123 PID: PID 102 SPN: 102 FMI: 4 Intake Manifold 1 Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 122 PID: PID 102 SPN: 102 FMI: 3 Intake Manifold 1 Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 115 PID: PID 190 SPN: 612 FMI: 2 Engine Magnetic Speed/Position Lost Both of Two Signals- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 111 PID: SID 254 SPN: 629 FMI: 12 Engine Control Module Critical Internal Failure- Bad Intelligent Device or Component
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8214 PID: SPN: 521218 FMI: 3/3 Connectivity Module GPS External Antenna – Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 8213 PID: SPN: 521218 FMI: 5/5 Connectivity Module GPS External Antenna – Current Below Normal or Open Circuit