Meteen naar de content

Telegram : @Diezel365

Cummins ISX11.9 CM2250 (2010-12) Fault Code: 595 PID: 103 SPN: 103 FMI: 0 Turbocharger 1 Speed- Data Valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe turbocharger speed sensor is a variable reluctance speed sensor. It consists of a coil of wire and an iron core. The target on the turbocharger shaft is a ground flat in the center of the shaft. As the flat on the turbocharger shaft spins past the speed sensor, a signal is generated. The ECM interprets this signal and converts it to a turbocharger speed reading.

Component LocationThe turbocharger speed sensor is mounted in the center housing of the turbocharger.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is operating.

Conditions for Setting the Fault CodesThe ECM detects that the turbocharger speed is detected to be greater than 150,000 rpm for more than 5 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.The ECM will estimate turbocharger speed.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop-and-go city driving and steady state highway driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.

To validate the repair using a Chassis Dynamometer Test, utilize a routine that incorporates acceleration and motoring events, steady state highway operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.

The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp after the diagnostic runs and passes.For On-Board Diagnostic (OBD) engines, the ECM will turn off the MIL after three consecutive trips where the diagnostic runs and passes.The ?Reset All Faults? command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Damaged turbocharger speed sensorDamaged engine harnessDamaged ECM.If the fault occurs intermittently, look for causes of intermittent open or short circuits in the turbocharger speed sensor circuit (including the speed sensor pigtail connector).

Possible Cause:1) Turbocharger Speed sensor failure2) Engine harness/ Connector failure3) ECM calibration

Cummins ISX11.9 CM2250 (2010-12) Fault Code: 585 PID: SID 39 SPN: 677 FMI: 4 Starter Relay Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 584 PID: SID 39 SPN: 677 FMI: 3 Starter Relay Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 559 (X) PID: 157 SPN: 157 FMI: 18 Injector Metering Rail 1 Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 559 (CL) PID: 157 SPN: 157 FMI: 18 Injector Metering Rail 1 Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 559 (B) PID: SPN: 157 FMI: 18 Injector Metering Rail 1 Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 556 PID: 101 SPN: 101 FMI: 0 Crankcase Pressure- Data Valid But Above Normal Operating Range- Most Severe Level