Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3737 PID: SID 115 SPN: 1675 FMI: 31 Engine Starter Mode Overcrank Protection- Condition Exists

Circuit DescriptionThe overcrank protection feature (or starter lockout) is designed to prevent damage to the starter motor during hard start conditions. Excessive cranking of the engine can cause the starter motor to overheat, resulting in permanent damage. When excessive engine cranking is detected, the overcrank protection feature locks out the starter until the starter motor has adequately cooled, and is safe to operate again.

Component LocationThe overcrank protection feature is controlled by the ECM, and can not be modified.

Conditions for Running the DiagnosticsThis diagnostic runs when the engine is being started.

Conditions for Setting the Fault CodesThe ECM detects that the starter motor has been engaged for a long enough period of time that continued cranking can cause starter damage. This cumulative time includes continuous cranking and/or a series of shorter cranking attempts within a certain time window.

Action Taken When the Fault Code is ActiveThe starter is locked out and the engine can not be cranked over until the starter motor has adequately cooled.The ECM will flash the Wait to Start lamp (if equipped) until the starter motor has adequately cooled (up to 150 seconds).Conditions for Clearing the Fault CodeThe fault code status displayed by INSITE? electronic service tool will change to INACTIVE and the Wait To Start lamp will stop flashing immediately after the starter cool down period has expired, which can take up to 150 seconds.

The ?Reset All Faults? command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the Malfunction Indicator Lamp (MI)L for On-Board Diagnostic (OBD) applications

Shop TalkThis is an information only fault code, and does not indicate an issue with the starter.

Possible Cause:1) ECM calibration

Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3736 PID: SID 27 SPN: 3360 FMI: 11 Aftertreatment Diesel Exhaust Fluid Controller- Root Cause Not Known
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3734 PID: 102 SPN: 862 FMI: 4 Crankcase Breather Filter Heater Circuit- Voltage Below Normal or Shorted to Low Source
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3733 PID: SPN: 862 FMI: 3 Crankcase Breather Filter Heater Circuit- Voltage Above Normal or Shorted to High Source
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3727 PID: SID 254 SPN: 5571 FMI: 7 High-Pressure Common Rail Fuel Pressure Relief Valve- Mechanical System Not Responding or Out of Adjustment
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3726 PID: SPN: 3216 FMI: 16 Aftertreatment Intake Nox- Data valid But Above Normal Operating Range- Moderately Severe Level
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3725 PID: 102 SPN: 3216 FMI: 10 Aftertreatment Intake Nox Sensor- Abnormal Rate of Change