Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3717 PID: SPN: 3226 FMI: 13 Aftertreatment Outlet Nox Sensor- Out of Calibration

Circuit DescriptionThe aftertreatment outlet NOx sensor is a smart device and receives commands from the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment outlet NOx sensor location can vary, depending on engine application. It is usually located in the exhaust system at the outlet of the aftertreatment selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesA mismatch has been detected between the engine’s electrical system voltage and the NOx sensor voltage rating.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will turn off the MIL after three consecutive trips where the diagnostic runs and passes.The ?Reset All Faults? command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Calibration incompatibility between aftertreatment outlet NOx sensor and ECM calibrationSystem voltage incorrect for installed aftertreatment outlet NOx sensor part numberIncorrect aftertreatment outlet NOx sensor is installed in exhaust system.Reference the appropriate original equipment manufacturer (OEM) wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and data link communication issues with aftertreatment components, it is highly recommended that the OEM power distribution center fuses and relays be thoroughly checked for loose, missing, or intermittent connections

Possible Cause:1) ECM calibration

Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3716 PID: SPN: 188 FMI: 18 Engine Speed At Idle- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3715 PID: SPN: 188 FMI: 16 Engine Speed At Idle- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3714 PID: SID 115 SPN: 1569 FMI: 31 Engine Protection Torque Derate- Condition Exists
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3713 PID: SID 254 SPN: 5491 FMI: 7 Aftertreatment Diesel Exhaust Fluid Line Heater Relay- Mechanical System Not Responding or Out of Adjustment
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3712 PID: 105 SPN: 5246 FMI: 0 Aftertreatment SCR Operator Inducement- Data Valid But Above Normal Operational Range- Most Severe Level
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 3697 PID: SID 254 SPN: 630 FMI: 12 Engine Control Module Calibration Memory- Bad Intelligent Device or Component