Cummins ISX CM870 (2003-06) Fault Code: 595 PID: P103 SPN: 103 FMI: 0/16 Turbocharger 1 Speed – Data Valid But Above Normal Operating Range – Moderately Severe Level. High turbocharger speed has been detected by the engine control module (ECM).

NOTE: This fault code may become active if the protective shipping sticker is not removed from the port located on the end opposite of the connector. When installing a new turbocharger control valve, make sure the adhesive cover is removed.

This fault can come active any time the key is on and the ECM detects turbocharger speed greater than a calibration limit. This fault can be caused by malfunctions in the following components:

1)Turbocharger speed sensor2)Engine harness3)ECM power supply or grounds4)Electronic vehicle accessories which emit excessive electromagnetic interference.This fault becomes inactive any time the ECM detects a valid turbocharger speed.

If the fault occurs intermittently:

1)Look for causes of intermittent open circuit or short circuits in the turbocharger speed sensor circuit (including the speed sensor pigtail connector).2)Look for sources of electronic noise such as poorly installed vehicle electronic components.3)Make sure the vehicle chassis grounds are in good condition.4)Make sure the ECM power supply and ground circuits are in good condition and that this power supply is not shared with other vehicle electronics.

Possible repairs:

1)Replace the turbocharger speed sensor.2)Repair or replace the engine harness.3)Replace the EMC.

Cummins ISX CM870 (2003-06) Fault Code: 585 PID: S39 SPN: 677 FMI: 4/4 Starter Relay Driver Circuit – Voltage Below Normal or Shorted to Low Source. Low voltage detected at starter lockout circuit.
Cummins ISX CM870 (2003-06) Fault Code: 584 PID: S39 SPN: 677 FMI: 3/3 Starter Relay Driver Circuit – Voltage Above Normal or Shorted to High Source. Open circuit or high voltage detected at starter lockout circuit.
Cummins ISX CM870 (2003-06) Fault Code: 559 PID: P157 SPN: 157 FMI: 1/18 Injector Metering Rail 1 Pressure – Data Valid But Below Normal Operating Range – Moderately Severe Level. The engine control module (ECM) has detected that fuel pressure is lower than commanded pressure.
Cummins ISX CM870 (2003-06) Fault Code: 551 (SSS) PID: S230 SPN: 558 FMI: 4/4 Accelerator Pedal Idle Validation Circuit – data incorrect. No voltage detected simultaneously on both idle validation and off-idle validation switches.
Cummins ISX CM870 (2003-06) Fault Code: 551 (ISS) PID: S230 SPN: 558 FMI: 4/4 Accelerator Pedal Idle Validation Circuit – data incorrect. No voltage detected simultaneously on both idle validation and off-idle validation switches.
Cummins ISX CM870 (2003-06) Fault Code: 551 (NISS) PID: S230 SPN: 558 FMI: 4/4 Accelerator Pedal Idle Validation Circuit – data incorrect. No voltage detected simultaneously on both idle validation and off-idle validation switches.