Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
The intake manifold 1 temperature sensor measures the temperature of the charge-air as it passes through the intake manifold. Possible causes of this fault code include:
1)Plugged charge air cooler fins 2)Restricted airflow through the charge air cooler 3)An undersized charge air cooler 4)High turbocharger compressor outlet temperature.