Allison WTEC II Fault Code: 24 PID: SPN: 23 FMI: Sump fluid temperature, hot

Geplaatst door Diezel Solutions op

Main code 24 indicates the ECU has detected either a high or low fluid temperature in the transmission sump (via the sump temperature sensor in the internal harness). No upshifts are allowed above a calibration range when Code 24 23 is set. A related code is 33 12 which indicates a temperature reading outside the usable range of the sensor and indicates a probable sensor failure.

Meer lezen →


Allison WTEC II Fault Code: 25 PID: SPN: 00 FMI: Output speed sensor detected at 0 output rpm, Low

Geplaatst door Diezel Solutions op

Main code 25 occurs if the output speed sensor reports a zero speed reading while both engine and turbine speeds are approximately equal, turbine speed is above a calibration value, and neutral is not selected or commanded. Possible Causes:1. Output speed sensor has failed2. The required oncoming clutch or clutches did not come on.

Meer lezen →


Allison WTEC II Fault Code: 25 PID: SPN: 11 FMI: Output speed sensor, detected at 0 output rpm, 1st

Geplaatst door Diezel Solutions op

Main code 25 occurs if the output speed sensor reports a zero speed reading while both engine and turbine speeds are approximately equal, turbine speed is above a calibration value, and neutral is not selected or commanded. Possible Causes:1. Output speed sensor has failed2. The required oncoming clutch or clutches did not come on. Code 25 11 can be generated by a false turbine speed reading. This may be due to crosstalk between solenoid and turbine speed sensor circuits caused by direct wire-to-wire short or by water in the electrical connectors.

Meer lezen →


Allison WTEC II Fault Code: 25 PID: SPN: 22 FMI: Output speed sensor, detected at 0 output rpm, 2nd

Geplaatst door Diezel Solutions op

Main code 25 occurs if the output speed sensor reports a zero speed reading while both engine and turbine speeds are approximately equal, turbine speed is above a calibration value, and neutral is not selected or commanded. Possible Causes:1. Output speed sensor has failed2. The required oncoming clutch or clutches did not come on.

Meer lezen →


Allison WTEC II Fault Code: 25 PID: SPN: 33 FMI: Output speed sensor, detected at 0 output rpm, 3rd

Geplaatst door Diezel Solutions op

Main code 25 occurs if the output speed sensor reports a zero speed reading while both engine and turbine speeds are approximately equal, turbine speed is above a calibration value, and neutral is not selected or commanded. Possible Causes:1. Output speed sensor has failed2. The required oncoming clutch or clutches did not come on.