DESCRIPTION:
CPC output 4 07 short to voltage.
MONITORED PARAMETER:
CPC output 4/7.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
Two seconds
DASH LAMPS:
CEL
ENGINE REACTION:
None
VERIFICATION:
Engine on with output activation.
PROBABLE CAUSES:
Wiring problem between pin 1 and/or 3 of the turbocharger actuator connector and pin 35 and/or 93 of the 120-pin ECM connection.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 704 FMI 3 (CPC) Digital Output 4 07 Circuit Failed High
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 704 FMI 3 (CPC) High Exhaust System Temperature Lamp
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 703 FMI 5 (CPC) Water In Fuel (WIF) Sensor Indicates an Open Circuit in the Wiring to Pin 09 of the CPC #3 Connector
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 703 FMI 4 (CPC) Digital Output 3 09 – Short to Ground on Pin 9 Circuit of the Common Powertrain Controller #3 Connector
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 703 FMI 3 (CPC) Digital Output 3 09 – Short to Power/Open on Pin 9 of the Common Powertrain Controller #3 Connector