NOTE: This code sets when the common powertrain controller (CPC) detects the voltage on the sensor supply circuits is out of range.
DESCRIPTION:
Remote accelerator pedal supply voltage circuit failed low.
MONITORED PARAMETER:
Remote accelerator pedal voltage.
TYPICAL ENABLING CONDITIONS:
Always on
MONITOR SEQUENCE:
Key on
EXECUTION FREQUENCY:
None
TYPICAL DURATION:
None
DASH LAMPS:
CEL
ENGINE REACTION:
Idle only
VERIFICATION:
1. Ignition key
2. Cycle on
POSSIBLE CAUSES:
1. Remote accelerator pedal assembly.
2. Circuit fault.
3. Fault within the CPC.
4. Improper configuration of the CPC.
NOTE: This code always indicates to replace the MCM.