DESCRIPTION:
Diesel exhaust fluid (DEF) system circuit voltage above normal, or shorted to high source.
MONITORED PARAMETER:
DEF dosing unit voltage.
TYPICAL ENABLING CONDITIONS:
DEF dosing enabled.
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Continuous when enabling conditions met.
TYPICAL DURATION:
Two seconds
DASH LAMPS:
None
ENGINE REACTION:
Derate 25%
VERIFICATION:
Key off five minutes after repair.
PROBABLE CAUSES:
1. DEF doser valve harness connector.
2. DEF metering unit failure.
3. Wiring between DEF doser valve harness and the ECM.