NOTE: This code indicated a motor control module (MCM) internal failure. Replace the MCM.
DESCRIPTION:3V Sensor supply bank 2 circuit failed low.
MONITORED PARAMETER:MCM 3V internal power supply.
TYPICAL ENABLING CONDITIONS:Always enabled
MONITOR SEQUENCE:None
EXECUTION FREQUENCY:Always enabled
TYPICAL DURATION:Two seconds
DASH LAMPS:1. MIL2. CEL
VERIFICATION:Engine Idle: One minute.
NOTE: This code always indicates to replace the MCM.
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3512 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3511 FMI 4 (MCM) 3V Sensor Supply Bank 1 Circuit Failed Low
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3511 FMI 4 (CPC) Remote Accelerator Pedal Supply Voltage Circuit Failed Low
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3511 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3511 FMI 3 (CPC) Remote Accelerator Pedal Supply Voltage Circuit Failed High
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3510 FMI 8 (CPC) 2-Channel Accelerator Pedal Supply Voltage Missing