Circuit DescriptionThe ECM uses diagnostic software to verify injector operation. During selected conditions, each injector is fired. The fueling quantity and timing are then compared to a specified threshold.
Component LocationThe engine harness connects the ECM to the pass-through connector(s) that are located in the rocker housing. Internal injector harnesses are located under the valve cover and connect the injectors to the engine harness at the pass-through connector(s).
Conditions for Running the DiagnosticsThis diagnostic runs periodically during engine operation.
Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected a fueling timing or quantity error for the specified injector.
Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeIt is necessary to use the “Reset All Faults” command in INSITE™ electronic service tool to clear this fault and extinguish the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL).
Shop TalkThis fault code is intended to identify fueling quantity and timing issues.
Possible Cause:1) Cylinder number 1 fuel Injector failure2) ECM calibration