DESCRIPTION:This fault sets when the Motor Control Module (MCM) detects a short to ground on the bank one sensor voltage supply (Pins 58 or 117..
MONITORED PARAMETER:5V internal power supply.
DASH LAMPS:1. MIL2. CEL
VERIFICATION:Engine Idle: One minute.
PROBABLE CAUSES:Short to power from the MCM pins to a sensor:1. Pin 58, charge air cooler outlet pressure sensor.2. Pin 102, charge air cooler pressure sensor.
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3509 FMI 3 (MCM) 5V Sensor Supply Bank 1 Circuit Failed High
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3509 FMI 3 (ACM) The 5V Sensor Supply Bank 1 Circuit Failed High
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3482 FMI 7 (MCM) Fuel Cutoff Valve Failed Self Test
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3482 FMI 5 (MCM) Fuel Cut-Off Valve Circuit Failed Open
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3482 FMI 4 (MCM) Fuel Cut-Off Valve Circuit Failed Low
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3482 FMI 3 (MCM) Fuel Cut-Off Valve Circuit Failed High