Skip to content

Telegram : @Diezel365

Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3719 FMI 16 (ACM) Soot Level High

NOTE: Do not interrupt regeneration once it has been initiated.

When this code is detected, the operator has two minutes to execute the entry conditions:1. Cycle clutch switch (Manual transmission).2. Cycle parking brake.3. Cycle neutral switch (Automatic transmission).4. Then initiate regeneration request.

NOTE: If this procedure is not completed within this time limit, the engine will shut down and the regeneration procedure must be restarted.

NOTE: When this code is active, driver has 2 minutes to execute the entry conditions: Cycle clutch switch, parking brake, neutral switch (automatics), and then initiate the regen process. If not completed, engine will shut down and regen procedure must be restarted.

PROBABLE CAUSES:Perform a parked regeneration.

Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3719 FMI 15 (ACM) Diesel Particulate Filter Regeneration Lamp is Flashing in “Regen Zone 3”
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3719 FMI 0 (ACM) Soot Level Very High
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3716 FMI 31 (MCM) High Idle Regeneration Aborted – Low Coolant Temp
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3713 FMI 31 (MCM) High Idle Regeneration Aborted – Low Regeneration Temperature
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3711 FMI 31 (MCM) High Idle Regeneration (Aborted) – Low Exhaust Temperature
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3696 FMI 13 (CPC) Diesel Particulate Filter Regen Force MUX Switch Message Contains SNV Indicator