Cummins ISB4.5 CM2150 Fault Code: 2373 PID: 131 SPN: 1209 FMI: 3 Exhaust Gas Pressure Sensor Circuit – Voltage Above Normal or Shorted to High Source.
Posted by Diezel Solutions on
Circuit DescriptionThe exhaust gas pressure sensor is used to measure exhaust gas pressure in the exhaust manifold. This information is used by the engine control module (ECM) to control emissions and exhaust gas recirculation (EGR) valve operation. The ECM provides a 5 volt supply to the exhaust gas pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The exhaust gas pressure sensor provides a signal to the ECM on the exhaust gas pressure sensor signal circuit. This sensor signal voltage changes based on the pressure in the exhaust manifold. Component LocationThe...
Cummins ISB4.5 CM2150 Fault Code: 2374 PID: 131 SPN: 1209 FMI: 4 Exhaust Gas Pressure Sensor Circuit – Voltage Below Normal or Shorted to Low Source.
Posted by Diezel Solutions on
Circuit DescriptionThe exhaust gas pressure sensor is used to measure exhaust gas pressure in the exhaust manifold. This information is used by the engine control module (ECM) to control emissions and exhaust gas recirculation (EGR) valve operation. The ECM provides a 5 volt supply to the exhaust gas pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The exhaust gas pressure sensor provides a signal to the ECM on the exhaust gas pressure sensor signal circuit. This sensor signal voltage changes based on the pressure in the exhaust manifold. Component LocationThe...
Cummins ISB4.5 CM2150 Fault Code: 2377 PID: SID 33 SPN: 647 FMI: 3 Fan Control Circuit – Voltage Above Normal or Shorted to High Source.
Posted by Diezel Solutions on
Circuit DescriptionThe fan control circuit is a device used by the engine to control the fan operation. When the engine control module (ECM) energizes the fan control circuit, the engine fan is engaged. The fan control circuit utilizes a pulse width modulated (PWM) signal. A pulse width modulated (PWM) signal is a pulsed voltage signal between 0-VDC and system voltage. The frequency of the pulsed voltage signal is dependent on the application requirement. There are two types of fans supported by the fan control circuit; variable speed and ON/OFF. Use INSITE™ electronic service tool to determine which fan type is...
Cummins ISB4.5 CM2150 Fault Code: 238 PID: SID 232 SPN: 3511 FMI: 4 Sensor Supply 3 Circuit – Voltage Below Normal or Shorted to Low Source.
Posted by Diezel Solutions on
Circuit DescriptionThe sensor supply 3 circuit provides a 5 volt supply to the primary engine speed/position sensor. Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running. Conditions for Setting the Fault CodesThe electronic control module (ECM) detects the sensor supply 3 signal voltage is less than a calibratible value for more than 1 second. Action Taken When the Fault Code is Active– The ECM illuminates the amber CHECK ENGINE light and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.-The backup engine speed sensor...
Cummins ISB4.5 CM2150 Fault Code: 2387 PID: SID 27 SPN: 641 FMI: 7 VGT Actuator Driver Circuit (Motor) – Mechanical System Not Responding or Out of Adjustment.
Posted by Diezel Solutions on
Circuit DescriptionThe VGT is electronically activated by the VGT actuator. The VGT actuator is a smart device that receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports errors back to the primary engine ECM with the J1939 data link. Component LocationThe VGT actuator is located on the turbocharger bearing housing. Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running. Conditions for Setting the Fault CodesThis fault code will set when the actual VGT...