Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6782 PID: SPN: 4766 FMI: 2/20 Aftertreatment 1 Diesel Oxidation Catalyst Outlet Gas Temperature Sensor – Data Not Rational – Drifted High
Posted by Diezel Solutions on
Lamp:None Reason:An offset in the diesel particulate filter intake temperature sensor reading has been detected. Effect:Possible reduced engine performance. Circuit Description:The aftertreatment exhaust gas temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment exhaust gas temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment exhaust gas temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, aftertreatment diesel particulate filter outlet temperature, and...
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6783 PID: SPN: 4766 FMI: 2/21 Aftertreatment 1 Diesel Oxidation Catalyst Outlet Gas Temperature Sensor – Data Not Rational – Drifted Low
Posted by Diezel Solutions on
Lamp:None Reason:An offset in the diesel particulate filter intake temperature sensor reading has been detected. Effect:Possible reduced engine performance. Circuit Description:The aftertreatment exhaust gas temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment exhaust gas temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment exhaust gas temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, aftertreatment diesel particulate filter outlet temperature, and...
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6784 PID: SPN: 3246 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted High
Posted by Diezel Solutions on
Lamp:None Reason:An offset in the diesel particulate filter outlet temperature sensor reading has been detected. Effect:Possible reduced engine performance. Circuit Description:The aftertreatment exhaust gas temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment exhaust gas temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment exhaust gas temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, aftertreatment diesel particulate filter outlet temperature, and...
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6785 PID: SPN: 3246 FMI: 2/21 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted Low
Posted by Diezel Solutions on
Lamp:None Reason:An offset in the diesel particulate filter outlet temperature sensor reading has been detected. Effect:Possible reduced engine performance. Circuit Description:The aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate...
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6786 PID: SPN: 3610 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor – Data Not Rational – Drifted High
Posted by Diezel Solutions on
Lamp:None Reason:An offset in the diesel particulate filter outlet pressure sensor reading has been detected. Effect:Possible reduced engine performance. Circuit Description:The Engine Control Module (ECM) provides a 5 volt supply to the aftertreatment diesel particulate filter outlet pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The aftertreatment diesel particulate filter outlet pressure sensor provides a signal to the ECM on the aftertreatment diesel particulate filter outlet pressure sensor signal circuit. This sensor signal voltage changes based on the pressure at the outlet of the aftertreatment diesel particulate filter. Component Location:The...