PACCAR PX-8 CM2150 (2007-09) Fault Code: 431 PID: SID 230 SPN: 558 FMI: 2 Accelerator Pedal or Lever Idle Validation Circuit – Data Erratic, Intermittent, or Incorrect.

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.

1)This fault code is usually caused by an open circuit on either the idle validation on-idle or the idle validation off-idle signal circuit, a loose connection, uncalibrated accelerator pedal or lever assembly, or miswired idle validation switch.
2)When installing a new accelerator pedal or lever assembly, it must be calibrated before operating the engine. To calibrate the new accelerator pedal or lever assembly, turn the keyswitch to the ON position and fully depress and release the pedal or lever three times.

Possible repairs:

1)Connect the ISS to the OEM harness.
2)Replace the ISS.
3)Replace the ECM.

PACCAR PX-8 CM2150 (2007-09) Fault Code: 429 PID: 97 SPN: 97 FMI: 4 Water-in-Fuel Indicator Sensor Circuit – Voltage Below Normal or Shorted to Low Source. Low voltage detected at the water-in-fuel circuit.
PACCAR PX-8 CM2150 (2007-09) Fault Code: 428 PID: 97 SPN: 97 FMI: 3 Water-in-Fuel Indicator Sensor Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at the water-in-fuel circuit.
PACCAR PX-8 CM2150 (2007-09) Fault Code: 427 PID: SID 231 SPN: 639 FMI: 9 J1939 Datalink – Abnormal Update Rate. Communication between the electronic control module (ECM) and another device on the SAE J1939 data link has been lost.
PACCAR PX-8 CM2150 (2007-09) Fault Code: 418 PID: 97 SPN: 97 FMI: 0 Water-In-Fuel Indicator – Data Valid but Above Normal Operatibng Range – Least Severe Level. Water has been detected in the fuel filter.
PACCAR PX-8 CM2150 (2007-09) Fault Code: 415 PID: 100 SPN: 100 FMI: 1 Engine Oil Rifle Pressure – Data Valid But Below Normal Operating Range – Most Severe Level. Oil pressure signal indicates oil pressure is below the engine protection critical limit.
PACCAR PX-8 CM2150 (2007-09) Fault Code: 386 PID: SID 212 SPN: 3509 FMI: 3 Sensor Supply 1 Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at sensor supply number 1 circuit.
Back to blog