Overview:
This code indicates the transmission was unable to move the front box to neutral, during a shift request.
Detection:
The transmission detects this by attempting the same shifter actions five times and not sensing the desired position.
Fallback:
This causes an In Place Fallback.
Required Tools:
1) Basic Hand Tools
2) AutoSelect/AutoShift Troubleshooting Guide
Possible Causes:
1) Low power to gear select motor
2) Failed gear select sensor
3) Malfunctioning electric shifter
4) Malfunctioning yoke/clutch/mainshaft
5) Failed shift block
6) Failed or misaligned shift block
7) Electric shifter calibration
8) Dragging clutch
9) Torque locked in gear
Eaton Gen 1 (AutoShift) Fault Code: 65 PID: SID 251 FMI: 4 Low Motor Voltage
Eaton Gen 1 (AutoShift) Fault Code: 63 PID: SID 40 FMI: 6 Gear Select Motor
Eaton Gen 1 (AutoShift) Fault Code: 63 PID: SID 40 FMI: 5 Gear Select Motor
Eaton Gen 1 (AutoShift) Fault Code: 61 PID: SID 39 FMI: 6 Rail Select Motor
Eaton Gen 1 (AutoShift) Fault Code: 61 PID: SID 39 FMI: 5 Rail Select Motor
Eaton Gen 1 (AutoShift) Fault Code: 58 PID: PID 191 FMI: 2 Output Shaft Speed Sensor