DESCRIPTION:
3V sensor supply bank 1 circuit high voltage detected.
MONITORED PARAMETER:
Motor Control Module (MCM) 3V internal power supply.
TYPICAL ENABLING CONDITIONS:
Circuit voltage greater than 3.2 Volts.
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
None
VERIFICATION:
Engine Idle (One minute).
PROBABLE CAUSES:
Short to power on one of the following from the main 120-pin ECM connector:
1. Pin 29 – DOC outlet temperature sensor.
2. Pin 88 – DOC inlet temperature sensor, DOC outlet temperature sensor, DPF inlet temperature sensor, DPF outlet temperature sensor.