The ECM detects the following conditions:
•There is a high current condition (short circuit) in auxiliary output 01.
Probable Causes:
1) ECM Connector/harness
2) Shift solenoid failure
3) Shift solenoid relay
4) Wiring between shift solenoid and ECM
5) Gear ratios are programmed incorrectly in the ECM